| . |
The experiments in this field are concluded. The following
result can be considered as established and adequately based on scientific
research:
If any persons are to be sterilized permanently, this result can only be
attained by applying X-rays in a dosage high enough to produce castration with
all its consequences, since high X-ray dosages destroy the internal secretion
of the ovary, or of the testicles, respectively. Lower dosages would only
temporarily paralyze the procreative capacity. The consequences in question are
for example the disappearance of menstruation, climacteric phenomena, changes
in capillary growth, modification of metabolism, etc. In any case, attention
must be drawn to these disadvantages.
The actual dosage can be given in various ways, and the irradiation can take
place quite imperceptibly. The necessary local dosage for men is 500-600 r, for
women 300-350 r. In general, an irradiation period of 2 minutes for men, 3
minutes for women, with the highest voltage, a thin filter and at a short
distance, ought to be sufficient. There is, however, a disadvantage that has to
be put up with: as it is impossible unnoticeably to cover the rest of the body
with lead, the other tissues of the body will be injured, and radiologic
malaise, the so-called "Roentgenkater", will ensue. If the X-ray
intensity is too high, those parts of the skin which the rays have reached will
exhibit symptoms of burns varying in severity in individual cases
in the course of the following days or weeks.
One practical way of proceeding would be, for instance, to let the persons to
be treated approach a counter, where they could be asked to answer some
questions or to fill in forms, which would take them 2 or 3 minutes. The
official sitting behind the counter could operate the installation in such a
way as to turn a switch which would activate the two valves simultaneously
(since the irradiation has to operate from both sides). With a two-valve
installation about 150-200 persons could then be sterilized per day, and
therefore, with 20 such installations as many as 3,000-4,000 persons per day.
In my estimation a larger daily number could not in any case be sent away for
this purpose. As to the expenses for such a two-valve system, I can only give a
rough estimate of approximately 20,000-30,000 RM. Additionally, however, there
would be the cost of the construction of a new building, because adequately
extensive protective installations would have to be provided for the officials
on duty.
In summary, it may be said that, having regard to the present state of
radiological technique and research, mass sterilization by means of X-rays can
be carried out without difficulty. However, seems to be impossible to do this
in such a way that the persons con- [...cerned]
720
|